With any process equipment, it is necessary to understand causes and effects of failure modes. This is true for most designs, but it is especially important at Armstrong Chemtec, where our clients often handle dangerous and even lethal substances. Prioritizing safety under these conditions means identifying the potential failure points and designing ways to prevent or at least minimize them. This extends to secondary or more backups taken as additional safety measures. Let’s look at some examples of common problems, and what steps we take to try to prevent them from an engineering perspective.
Failure mode #1: Element burnout from low or no flow
One of the most common failures we have identified is element burnout from either a low- or a no-flow process fluid. Unlike a shell and tube heat exchanger, electric heaters are constant flux. That means the heat is produced regardless of whether or not it is absorbed by a process fluid, and heated, non-wetted elements will eventually burn out. The elements are designed for constant contact with a moving fluid to carry away the heat produced, and when that ceases, the element produces the same heat regardless. This heat is instead absorbed by the element sheath, causing the element to eventually overheat and burnout.
This is a serious problem because of the knock-on effect, as if one or two elements fail, the remaining elements may be required to run hotter than designed to compensate for the lost heat. This can lead to further element failure, downtime, replacement costs, and product degradation.
Example solution: Thermocouples and redundancies
Within every Armstrong Chemtec immersion heater, there are a minimum of two often K-type duplex thermocouples which are brazed or welded directly on to the heating elements. These thermocouples serve to measure the skin temperature of an element, communicating live data back to the control panel, through a 4-20 milliamp signal to the terminal box. If the control panel registers an increase of heat due to low- or no-flow issues, the system automatically trips, thus preventing further failure.
We include two of these thermocouples as an extra safety precaution, just in case one is damaged or faulty. This is more than required, but that’s the best defense against potentially damaging failures.
Failure mode #2: Moisture ingress and shorting
A second potential point of failure involves electrical components. When a junction box is opened during maintenance, ambient air — and the moisture it carries — can reach the electrical components inside. Once the terminal box is closed and the now trapped air reaches its dew point, there is moisture ingress within the terminal box. This moisture can condense, causing short circuits where the elements are connected to the power supply.
Heating element construction includes an electrical insulation, magnesium oxide, within each heating element. Magnesium oxide is hygroscopic, acting to attract and absorb any free water. That means if moisture is present, there could be a greater risk of an electrical short circuit.
Example solutions: ACH and desiccants
To limit moisture ingress, we rely on the use of different methods. The first is a built-in anti-condensation heater, or ACH, inside each junction box. This small heater cycles on and off based on a pre-set dew point, keeping the internal temperature of the box above the condensation temperature. The use of an ACH is an especially good idea for equipment that operates in areas of increased humidity and salinity, like the Gulf Coast.
A second method we use to keep hydration at bay is the inclusion of desiccants around the interior of junction boxes. This relatively low-cost solution works great as a backup, just in case the ACH malfunctions.
Failure mode #3: Fouling on the Element Sheaths
This problem is specific to higher viscosity or dirtier processes that lend themselves to fouling. Material buildup on an element sheath can lead to fouling that disrupts the heat transfer between heating element and process fluid, similarly to the failure associated with low- or no-flow. The electric heaters operate at a constant flux, and fouling acts to insulate the heating element sheath and trap heat in the heating element, which leads to overheated and failed elements.
An example of this is a heater in hydrocarbon usage. When hydrocarbon fluid is overheated by the temperature of the heat transfer surface, coking can occur with direct deposition on the heating elements. The buildup of coke causes poor heat transfer and therefore overheating of the element, causing failure.
Example solutions: Monitoring, maintenance, and manufacture
In certain processes, some fouling is to be expected, and periodic removal is an important part of regular maintenance. However, if fouling seems to be happening more frequently you should monitor your process. The heater thermocouples, as well as other temperature sensors upstream and downstream of the equipment, should indicate which areas are too hot and whether heat transfer is occurring between the bundle and process fluid as designed.
One reason why Armstrong Chemtec manufactures its own heating elements is to control the quality. Other manufacturers may outsource element manufacture but there is no guarantee that their quality is up to standard. No control over manufacturing techniques lends outsourced heating elements tend to fail more frequently. But design of heat flux and sheath skin temperatures provides greater control over performance.
For difficult fouling duties which cannot be met by immersion heaters, Armstrong Chemtec offers both electric radiant process heaters and electric impedance heaters.
If you’re curious about how we solve other engineering problems, or want to learn more about our products, please reach out.